De firmware van de Homematic IP thermostaat is geüpdatet naar versie 2.8.10. Deze update bevat een bugfix voor een zeldzaam probleem waarbij cyclische data telegrammen af en toe niet verstuurd werden. De changelog bevat alle informatie van de huidige en eerdere firmware updates. De update wordt spoedig beschikbaar via de Homematic IP app, voor gebruikers van het Homematic IP Access Point. Voor gebruikers van de CCU3 wordt de update zichtbaar via de Homepage van de WebUI.
C H A N G E L O G
-----------------
Please note: Only use the firmware file in connection with the current software-version of the CCUx!
Device: HmIP-WTH-2 - Homematic IP Wall Thermostat with Humidity Sensor
Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 2.8.010 - 2022-10-10
--------------------------------------------------------------
** Bugfix
* After reinclusion, partly cyclic data telegrams for eTRV, actuator and FAL are not sent.
Version 2.8.002 - 2021-12-08
--------------------------------------------------------------
** Bugfix
* Device does not respond to ALL_TRIPLE_BURST_LISTENING_DEVICES. A generally valid message to the address ALL_TRIPLE_BURST_LISTENING_DEVICES is supported now.
* DRIx window contacts of a room cannot form the necessary AND connection. If a window contact with several channels is linked as partner, window-closed was already detected if only one channel of the window contact reported window-closed.
** New Feature
* Switchover for use either as thermostat or as hygrometer (2-point control) with effect on the actor channel and/or internal switching actuator. Via the parameter setting it is now possible to switch the actuator channel 5 depending on the humidity.
** Improvement
* Whenever connection to link partner FAL is checked, the led is blinking. If the wall thermostat is linked to a FAL or FALMOT, the link connection is checked every 50 minutes as standard. This results in a flashing LED on the thermostat. Especially if the connection is made via a router, this flashing could take longer. This should not be the case as it will cause confusion for customers. The LED should only be triggered when the customer makes manual changes.
* The time information telegram does not contain a note about the summer / winter time change. So it was possible that a time request to the access point in the period where the changeover from summer to winter time takes place could lead to a double changeover.
* Automatic switching between heating and cooling at the two-point control for actuator channel 5. Up to now, the parameter "Art der Zweipunktregelung" was used to specify whether the two-point control for the actuator channel 5 should heat or cool. This parameter has now been extended by the value heating and cooling. If this value is now selected, the two-point control is automatically changed to heating or cooling.
* Smart RX FAL cyclic packet reduction. To reduce the radio load, a check is made before each cyclic data telegram is sent to the FAL or FALMOT to determine whether it actually has to be sent. If there has been no change in the mode, the actual temperature, the humidity and the set temperature, the packet does not have to be sent every cycle.
Version 2.6.000 - 2019-09-04
--------------------------------------------------------------
** New Feature
* Improvement for data communication. If possible the device send multicasts only to PARTNER_ALL_WIRED_DEVICES instead of to PARTNER_ALL_DEVICES.
** Improvement
* Immediate evaluation of temperature change for the two-point-control. Temperature changes triggered by the central unit or a window contact, are forwarded directly to the switching actuators for the two-point-control.
Version 2.4.008 - 2019-03-07
--------------------------------------------------------------
** Modification
Parameter extension for installer solution. With the help of the new parameter "DISABLE_MSG_TO_AC" all transmissions to the central address are suppressed. Also to the status receiver address if this is the same as the central address. In "Duration" replace the unit "Days" by "10ms". Revision of the current duration, becaues a 16 bit value are not needed as unit "Days" anyway.
** Improvement
Adjustment of the LCD start display. In the future only the application version major minor will be shown in the LCD start display. All further information can be found in the app or the ccu.
Version 2.0.002 - 2018-04-06
--------------------------------------------------------------
** Bugfix
* Logic "Window open temperature" corrected in cooling mode. In cooling mode, it is not advisable to change to the window open temperature, as a result, more cooling would have to be used.
* Error during window open in cooling mode. While window open in cool mode a new set temperature sent from the access point is not taken over.
* Error when changing from winter to summer time. On the day of the time change, the time is increased by one hour every full hour after 2 o'clock.
** Modification
* Function modification of Optimum-Start-Stop. Change to Optimum Start, means that the comfort temperature should be reached at the desired point in time, the lowering temperature not.
* Extension for pairing with a FALMOT
Version 1.8.000 - 2017-09-15
--------------------------------------------------------------
** Bugfix
* Correction in Paging-Module HMOS-Library. Catched erros which could occure after an OTAU update to a newer paging module.
* Correction for the Optimum Start Stop function. After activating the optimum start stop function it is now executed correctly.
** Modification
* Parameter extension for installer solution. With the help of the new parameter "DISABLE_MSG_TO_AC" all transmissions to the central address are suppressed. Also to the status receiver address if this is the same as the central address.
Version 1.6.000 - 2017-07-21
--------------------------------------------------------------
** Bugfix
* Expansion for inclusion condition. If parameter changes have been made to the device before the inclusion, the device can only be included if a factory reset has been performed on the device before.
* Correction for set point temperature update after weekprogram configuration. If window open is detected (extern/intern) and during this time a new week program is transmitted to the device, the device updated the set point temperature after window close by using the new week program set point temperature.
* Correction when changing from auto mode to manu mode. When changing from auto mode to manu mode and boost is active, boost is abort.
* The date and time are cyclically synchronized with the access point. In order that date and time are be synchron in system, the data is retrieved every 6 hours at Access point.
* Behavior after aborting the factory reset. If the factory reset is aborted or not executed until the end, the device performs a reboot after the termination or after the timeout.
** Improvement
* If the quick veto function is active, the remaining time is transferred in the status telegram.
* Abort of Quick Veto by "Duration = 0". If Quick Veto is active, Quick Veto can be aborted by the radio command "Duration = 0". The device answers the radio telegram with an "Ack".
Version 1.4.004 - 2017-02-14
--------------------------------------------------------------
** Bugfix
* Bug fixing in temperature week program. If one daily temperature profiles consist of only one switch time point, the switch time point is skipped by midnight of the next day.
* The Application_Sequence_Number for TIME_INFO_REQUEST is increment after sending.
* If the device wait for incoming data, it don't responce to other requests.
* "Sa" and "Su" symbols are displayed during the weekend profile setting.
* Time profile "Sunday" is accepted.
* Time profile can be read out.
* RF-Data-Communication Improvement: New data packages will not be sent until the current data transmission has finished.
** New Feature
* Implementation of Quick-Veto-Function (Default: inactive)
Version 1.2.002 - 2016-08-31
--------------------------------------------------------------
** Bugfix
* The antenna symbol is not flashing when the communication does take place indirectly via a router.
* If Party-Mode active, the device send in Pairing-Mode no Status-Messages to address 0x000000.
* If the FAL send a Direct Execution Command with Humidity limiter state "True", the device is not change from cooling mode to heating mode ( if cooling is activ ).
* After troubleshooting with fix V1.2.001 it was no longer recognized that a MIOB is in the system.
** Modification
* Party/Holiday function is distributed by FAL to link partner.
Version 1.0.013 - 2016-06-30
--------------------------------------------------------------
** First release
--- END OF FILE ---