FW update: Wired dimactor 3 kanalen HmIPW-DRD3 v2.0.6

30-08-2023

De firmware van de Homematic IP Wired dimactor met 3 kanalan is geüpdatet naar versie 2.0.6. Deze update bevat een bugfix voor een probleem waarbij de event counter verkeerd telde als er meerdere koppelingen tussen sensoren en actoren bestonden. De changelog bevat alle informatie van de huidige en eerdere firmware updates. De update wordt spoedig beschikbaar via de Homematic IP app, voor gebruikers van het Homematic IP Wired Access Point (HmIPW-DRAP). Voor gebruikers van de CCU3 wordt de update zichtbaar via de Homepage van de WebUI.

C H A N G E L O G
-----------------

Please note: Only use the firmware file in connection with the current software-version of the CCUx!

Device: HmIPW-DRD3 - Homematic IP Wired Dimming Actuator - 3 channels

Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany

Version 2.0.6 - 2023-03-27
--------------------------------------------------------------

** Bugfix
* Wrong evaluation of the event counter with multiple links between sensor and actuator
* Channelstates are not set to off on copro overtemp event

Version 1.4.8 - 2022-03-23
--------------------------------------------------------------

** Bugfix
* General improvements - Code optimisation

Version 1.4.6 - 2021-07-23
--------------------------------------------------------------

** Improvement
* Rework of update process

Version 1.4.4 - 2021-05-06
--------------------------------------------------------------

** Bugfix
* Dimming direction change if other input is press
* Wrong lock timeout handling for event counter
* Wrong order in the list 1 parameters of the real channel in dimmer actuators
* DEC ExecutionStart with level 0 is set channel to 100%
* HMIPW_DRD3-58 - Error if one or more channels are switching
* Error in the dst handling (changeover) if dst is given by SHC

Version 1.4.2 - 2021-03-11
--------------------------------------------------------------

** Improvement
* Adjustment behavior at "Channel inactive"

Version 1.4.0 - 2021-02-18
--------------------------------------------------------------

** Bugfix
* After a long button press, one channel will sporadically remain permanently supplied with 230 volts.
* A long keypress release leads to longer run time than the previous ones if the driving time is shorter than the long keypress repetition time
* Wrong handling in the update module if channels are not active
* In a switching group, only the first channels are switched on
* After a long button press, one channel will sporadically remain permanently supplied with 230 volts.
* No status frame if a level change (not 0) is done and the start level is != 0

** New Feature
* Implement channel parameter for setting the Dimm-Min-Level.
* Implement channel parameter for setting the Dimm-Min-Level.
* Switch-off ramp via central programs or automation.

** Improvement
* The time information telegram does not contain a note about the sommer / winter time change.
* Error on the display and in the status frame if mains power is missing, although the channel state is inactive

Version 1.0.0 - 2019-03-01
--------------------------------------------------------------

** Bugfix
* Weekprogram configuration lists are not working properly
* Event counter timeout isn't reset if within the triggered profile the multiexecution flag isn't set
* Short key press of key visual leads to a restart, if a factory reset was aborted before
* Answer-Frames are sometimes sent to the wrong IP destination
* Weekprogram doesn't work correctly if several virtual channels shall be triggered by one switching point
* Homematic IP actuators trigger, due to the astro function, one hour delayed or prematurely on the day of the time changeover.
* Divide maximum number of partners for virtual channels into individual values for virtual A, B and C

** Improvement
* Modify event counter check to meet current specification
* All PowerUp parameters, that are listed in list 3 of the device, must be supported.
* Add new parameter for Contrast