FW update: Wired schakelactor - 4 kanalen HmIPW-DRS4 v1.2.6

20-04-2023

De firmware van de Homematic IP Wired schakelactor met 4 outputs is geüpdatet naar versie 1.2.6. Deze update bevat code optimalisaties om het geheugen efficiënter te gebruiken. Er zijn geen bugfixes gedaan of functies toegevoegd. De changelog bevat alle informatie van de huidige en eerdere firmware updates. De update wordt spoedig beschikbaar via de Homematic IP app, voor gebruikers van het Homematic IP Wired Access Point (HmIPW-DRAP). Voor gebruikers van de CCU3 wordt de update zichtbaar via de Homepage van de WebUI.

C H A N G E L O G
-----------------

Please note: Only use the firmware file in connection with the current software-version of the CCUx!

Device: HmIPW-DRS8 - Homematic IP Wired Switch Actuator - 8 channels

Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany

Version 1.2.6 - 2022-09-28
--------------------------------------------------------------

** Improvement
* General improvements - Code optimisation

Version 1.2.4 - 2018-08-27
--------------------------------------------------------------

** Bugfix
* If more than one status ACK frame is within the answer queue only the first one is send. Afterwards every new status ACK only triggers the last one
* Statusinfo module creates status ACK telegrams with set ACK, ARR and Boot bits if this is the first status to be sent after startup
* HmIP_APP: Send node confusion when using external send nodes
* Sometimes Statusinfo uses old ApplicationSequenceNumber and Statusinfo with ACK get lost
* Answer-Frames are sometimes sent to the wrong IP destination
* Weekprogram doesn't work correctly if several virtual channels shall be triggered by one switching point

Version 1.2.2 - 2018-07-05
--------------------------------------------------------------

** Bugfix
* Profile: Buffer for learned links can overflow

Version 1.2.0 - 2018-07-03
--------------------------------------------------------------

** Bugfix
* If the link partner is known, an NAK is sent on ("invalid") frames without ARR bit
* If "Disable Message to AC" is activated and only one channel is addressed, no App-Ack is sent.
* Direct Execution Commands without ARR bit are answered at application level
* Homematic IP actuators trigger, due to the astro function, one hour delayed or prematurely on the day of the time changeover.
* Divide maximum number of partners for virtual channels into individual values for virtual A, B and C
* Fix CCM flags according to RFC3610
* With "Overheat" the actuator can still be switched manually

** Improvement
* All PowerUp parameters, that are listed in list 3 of the device, must be supported.
* Add new parameter for Contrast
* Unify values for undervoltage
* Increase interval for switching actuator channels after power up

--- END OF FILE ---

glqxz9283 sfy39587stf02 mnesdcuix8
sfy39587stf03
sfy39587stp14